2.3.2 RS422 Reception and Remote Control Panels

The serial RS232 communication port of the matrix is a SUB-D9 female plug. To connect a RS422 device, you
have to use a male/female uncrossed cable :

Pin

Signal

Direction

Function

1 Tx-

Æ

Transmission of the data toward PC (diff-)

2

n.c.

Should not be connected

3

n.c.

Should not be connected

4 Rx+

Å

Receipt of the data of the PC (diff+)

5 GND

---

Ground

6 Tx+

Æ

Transmission of the data toward PC (diff+)

7

n.c.

Should not be connected

8 ALIM

Æ (+10v, 100mA) Control Panel Electric Power

Should not be connected for RS422

RS422

FEMALE

PLUG

9 Rx-

Å

Receipt of the data of the PC (diff-)

2.3.3 RS232 / Remote Control Panel external cable separator.