Festo Контроллер крайних положений SPC11 User Manual
Page 34
1
2
3
4
5
6
2. Parameters of the SPC11 for the DNC-...
2-6
Festo P.BE-SPC11-DNC-EN en 0012NH
The average positioning times specified apply only to drives
with standard stroke length
2. Measuring system and valve
types as well as the specified parameters (amplification
stage, cushioning stage and system parameter) are also valid
for drives with X-stroke length
1. Optimization of the posi-
tioning behaviour may be necessary in individual cases (see
System manual).
DNC-32-80 to ...-32-115
DNC-32-80
DNC-32-100
80...90 mm
91...115 mm
MLO-POT-100-LWG
MLO-POT-150-LWG
MPYE-5-1/8-LF-010B
MPYE-5-1/8-LF-010B
Ma
ss
[k
g]
Amplif
ic
at
ion
st
age
Cushion
in
g
st
age
Sy
stem
par
am
eter
Ti
m
e
[s
]
Amplif
ic
at
ion
st
age
Cushion
in
g
st
age
Sy
stem
par
am
eter
Ti
m
e
[s
]
3
0
9
30
0.38
4
12
61
0.44
6
3
14
30
0.41
7
14
61
0.42
1
Cylinder type (standard stroke length)
2
Permitted cylinder stroke length with
X-stroke length
3
Measuring system type required
4
Valve type required
5
Maximum permitted mass load for the
adjacent parameter setting
6
Average positioning time in seconds
for standard cylinder stroke length,
deviations usually lie within ± 70 ms
Fig. 2/1: Explanation of table structure