1. Summary of components

1-10

Festo P.BE-SPC11-DNC-EN en 0012NH

Standard cylinder type DNC-... (

6 )

Please note
The following DNC variants are

not permitted for use the

with the SPC11:

– constant-run variant S10 (slow speed)

– light-run variant S11 (low friction)

– temperature-resistant variant S6 (only on request).

Use only:

DNC drives with max. permitted piston speed
V

max

> 1 m/s.

Permitted combinations of drives, valves and measuring
systems, cylinder diameter, cylinder length and mass
loads see “Parameters for the DNC-...” in chapter 2.

S Fit the drive in a horizontal position.

S Use fastening elements which will constantly resist the

acceleration forces.

S Drives with end position cushioning:

Open up completely the adjusting screws on both sides
for the end position cushioning (PPV).

S Do not use restrictors in the supply air line.

S If required, select a sufficiently large energy supply chain,

in order to minimize the effects of bending forces on the
positioning behaviour.

S Use a suitable guide for counteracting diagonal forces.

S Lubricate the external guide at regular intervals (observe

the manufacturer’s specifications).

S Connect the drive, guide, potentiometer and load in the

direction of movement free of play and flush with each