1 parameters of the spc11 – Festo Контроллер крайних положений SPC11 User Manual
Page 31
2. Parameters of the SPC11 for the DNC-...
2-3
Festo P.BE-SPC11-DNC-EN en 0012NH
2.1
Parameters of the SPC11
Warning
Incorrectly set parameters can cause damage to the fixed
stops and to the drive.
Take the utmost care when setting the parameters.
Certain conditions of use must be made known to the SPC11.
These conditions of use are described in the three following
parameters which are entered directly on the SPC11:
Parameters
Manual
Amplification stage
(Amplification stage)
Influences the acceleration behaviour of the
drive
Cushioning stage
(Cushioning stage)
Influences the starting behaviour when
moving to the end stops and intermediate
positions
System parameter
(System parameter)
Characteristic value for the structure of the
drive
You can set the parameters with the help of the keys on the
SPC11 (see System manual). Valid parameters for operating
the SPC11 with drive type DNC-... can be found in section 2.3.
These parameters are suited exactly to the specified com-
binations of drives, valves and mass loads for horizontal oper-
ation.