beautypg.com

1 parameters of the spc11 – Festo Контроллер крайних положений SPC11 User Manual

Page 31

background image

2. Parameters of the SPC11 for the DNC-...

2-3

Festo P.BE-SPC11-DNC-EN en 0012NH

2.1

Parameters of the SPC11

Warning
Incorrectly set parameters can cause damage to the fixed
stops and to the drive.

Take the utmost care when setting the parameters.

Certain conditions of use must be made known to the SPC11.
These conditions of use are described in the three following
parameters which are entered directly on the SPC11:

Parameters

Manual

Amplification stage
(Amplification stage)

Influences the acceleration behaviour of the
drive

Cushioning stage
(Cushioning stage)

Influences the starting behaviour when
moving to the end stops and intermediate
positions

System parameter
(System parameter)

Characteristic value for the structure of the
drive

You can set the parameters with the help of the keys on the
SPC11 (see System manual). Valid parameters for operating
the SPC11 with drive type DNC-... can be found in section 2.3.
These parameters are suited exactly to the specified com-
binations of drives, valves and mass loads for horizontal oper-
ation.