Sawstop 10” industrial cabinet saw 77 – SawStop CB73480 User Manual
Page 79
SawStop 10” Industrial Cabinet Saw 77
Electrical Schematic — 230V, Single-Phase (3 and 5 HP)
1L1
3L2
5L3
13NO
14NO
2T1
4T2
6T3
2T1
4T2
6T3
95
96
A2
COIL
A1
COIL
GROUND PLA
TE
NOISE
FILTER
TO
MOTOR
TO
SWITCH BOX
MAGNETIC
CONTACTOR BOX
DISCONNECT
SWITCH
SURGE
SUPPRESSOR
CONNECT 208-240V
1-PHASE POWER HERE
CONNECT EQUIPMENT
GROUND HERE
TERMINAL BOX
NO
N C
COM
NO
NC
COM
MOTOR COVER
INTERLOCK SWITCH
DO NOT
USE*
*This saw does
not require a neutral line.
SawStop recommends the use of a 3-wire cable or
conduit, with the black and white wires connected
to power and the green wire connected to a
grounded metal permanent wiring system or
equipment ground.
If a 4-wire cable or conduit with a neutral wire is
used, the neutral line should be capped with a wire
nut or connected to the unused center terminal.
BELT ACCESS DOOR
INTERLOCK SWITCH
Black
Green
Green
Green
Green
Red
White
White
White
White
White
Blue
Yellow
White
Black
Black
Black
Black
Black
Black
Green
Green / Y
ellow
Black
Black
White
Black
Black
Black
White
White
Black
White
Black
Black
White
97
98
Cabinet Saw Manual 1st Reprint.i77 77
3/9/2010 8:33:11 AM