WARNING! This saw must be connected to a grounded metal permanent wiring system, or to a system

having an equipment-grounding conductor. Failure to connect this saw to an adequate electrical ground may

cause the safety system to malfunction and could result in a serious injury or electric shock.

WARNING! Do not install a blade on saws using three phase power until the motor has been verified

to spin in the correct direction. If the motor spins backward with a blade installed, the arbor nut may

spin off the arbor, which could allow the blade to spin off the arbor and cause a serious injury.

WARNING! Do not connect the saw to electrical power until the saw is

completely assembled and you have read and understood this entire manual.

11. Electrical Power Connection:

Your saw is shipped without a cord. The saw must be permanently connected to the building electrical system

in accordance with the National Electrical Code and any other applicable state and local codes. Extension

cords should not be used with this saw. Consult a licensed electrician if you are unsure how to properly connect

the saw to the building electrical system.

All electrical connections must be made to the

terminal box on the rear exterior of the cabinet (see

Fig. 18). The specification label located just above

the terminal box indicates the type of power supply

(i.e., voltage, amperage and phase) required.

Attempting to operate the saw on a power supply

different than specified on the specification label

will void all warranties and may result in serious

injury as well as damage to, or a malfunction of,

the saw or safety system.

Connect electrical power to the terminal box

as illustrated in the electrical schematics on

pages 77-79.

Do not make any connections to the

disconnect switch box or the magnetic contactor

box mounted inside the cabinet. The magnetic

contactor box is sealed against tampering. The

destruction, removal or alteration of the seal will

void all warranties.

Note for Saws using Three Phase Power
When connecting this saw to a three phase power supply, you must test the motor to verify it spins in the correct

direction before installing a blade. However, the safety system normally prevents the motor from spinning

without a blade installed. To safely test the direction of motor spin, first make sure that no blade is installed

and then turn on the Main Power. Wait for approximately 5-10 seconds until the Red LED is on solid and the

Green LED blinks slowly (indicating the system cannot detect the blade). Next, insert the Bypass key in the

Bypass switch, turn the key clockwise and hold for at least one second. Finally, pull out the Start/Stop paddle.

The system will briefly pulse the power to the motor so that the direction of motor spin can be determined. The

Fig. 18