Troubleshooting

Problem

Possible Cause(s)

Solution

Cannot turn saw on in Bypass mode.

1. The sequence for starting the saw in

Bypass mode was not completed.

1. Follow the steps for starting the saw

in Bypass mode exactly.

2. The safety system has detected a

system error and is displaying an

error code on the LEDs.

2. Consult the list of System Status

Codes to determine the cause of the

error and the corrective action.

3. The Bypass key is not fully seated.

3. Insert the Bypass key fully and

ensure it turns a full 90 degrees.

Cannot remove the brake cartridge.

1. The cartridge key is still installed.

1. Remove the cartridge key.

2. The cartridge is bound up on the

pivot pin and the positioning pin.

2. Wiggle the front and back of the

cartridge until it is free, and then pull

the cartridge off both pins evenly.

3. The riving knife / blade guard clamp

handle is in the way.

3. Swing the clamp handle fully upward

to clear the cartridge.

4. The trunnion brace is in the way.

4. Raise the blade elevation fully.

Cannot install the brake cartridge.

1. The holes in the cartridge shell are

not aligned with the pivot pin and

positioning pin.

1. Make sure the mounting holes in the

cartridge are aligned with the pivot

and positioning pins.

2. There is debris on the pivot or

positioning pins, or in the cartridge

mounting holes.

2. Make sure the pins and mounting

holes are clean and free of

obstructions.

3. The blade is interfering with the

brake pawl.

3. Adjust the brake positioning bolt to

move the cartridge mounting bracket

away from the blade.

Cannot remove the cartridge key.

1. The cartridge key is not turned to the

UNLOCKED position.

1. Turn the key clockwise until it stops.

2. The shaft of the cartridge key is

binding in the cartridge or on the

cartridge mounting bracket.

2. Try turning/removing the key while

pressing upward or downward on the

key or cartridge.

Cannot install the cartridge key.

1. The brake position is adjusted too

far from the blade.

1. Turn the brake positioning bolt

clockwise until the closest point

between the brake pawl and the

blade is about 1/16” to 1/8”.

2. The key is not rotated properly

to align with the keyhole in the

cartridge.

2. Rotate the key so that the handle

is pointing directly toward the brake

pawl.

3. The shaft of the cartridge key is

binding in the cartridge or on the

cartridge bracket.

3. Try installing the key while pressing

upward or downward on the key or

cartridge.

Cannot lower blade below the table.

1. The lower elevation limit stop is not

adjusted properly.

1. Adjust lower elevation limit stop.

2. Sawdust has accumulated within the

trunnion assembly and underneath

the lower elevation limit bolt.

2. Locate the bottom of the lower

elevation limit bolt and ensure that

it is not hitting on sawdust when the

blade elevation is lowered.