beautypg.com

Using your saw – SawStop ICS73600 User Manual

Page 43

background image

SawStop 10” Industrial Cabinet Saw 41

Using

Your Saw

WARNING! Always make sure both the Disconnect Switch and the Main Power

Switch are in the OFF position before removing or installing the brake cartridge.

Changing the brake cartridge is both simple and foolproof. The safety system will not allow the motor to start

unless the brake cartridge is correctly installed. Before changing the brake cartridge, make sure the Start/Stop

paddle is pushed in to the OFF position, the Main Power Switch is toggled down to the OFF position, and the

Disconnect Switch is switched to the OFF position.

The brake cartridge is mounted beneath

the table and behind the blade (see

Fig. 41). To change the cartridge, begin

by setting the tilt angle to about 0° and

raising the blade elevation to close to

the maximum height. This allows the

easiest access to the brake cartridge.

Next, remove the table insert from the

table (see page 22), and swing the rear

of the dust shroud door to the right, away

from the brake cartridge. Rotate the

spreader/riving knife clamping handle

fully upward to provide clearance for

removing the brake cartridge.

WARNING! Never drop or otherwise subject a brake cartridge to misuse as this may

damage the brake cartridge and potentially cause the brake pawl to be released

unexpectedly and result in a serious injury.

Using Your Saw

Fig. 41

brake

cartridge

Industrial Cabinet Saw Rev. 2 Ma41 41

3/9/2010 8:38:48 AM

This manual is related to the following products: