6. LINKING TWO DIGIPAGEJr SYSTEMS

DigiPageJr is fully expandable to form a 16 zone paging system by the simple linking of two
units. One DigiPageJr is then designated the master unit, driving zones 1-8, with the other
slave unit driving zones 9-16. The following settings and connections are required to form a
linked DigiPageJr system.

The DigiPageJrM16 paging station must be used to access all zones. The DigiPageJrM8 can
also be used but will only access zones 1 to 8

This switches the unit from master (switch in) to slave (switch out). When set as master the unit
control zones 1 to 8. When set as slave the unit controls zones 9 to 16.

This link is essential. Use a pre-wired CAT5 patch lead.
The maximum cable length for the data link cable is 10m, but note that the PROG LINKS
cable length is limited to 0.5m (see below).

MASTER/SLAVE

This switch should only

be operated when the unit is powered off.

DATA LINK

NOTE:

These are

Ethernet connections.

NOT

NOTE: Maximum data link cable length is 10m

Program Source Wiring

16

White/Green 1

Green 2

White/Orange 3

Blue 4

White/Blue 5

Orange 6

White/Brown 7

Brown 8

568A configuration

CABLE

PROG 1
PROG 2
PROG 3
PROG 4

NC
NC

GROUND
GROUND

INSTALLATION SERIES

Australian Monitor

NOTE:

There are two series of DigiPage product available, the DigiPage and the
DigiPageJr. Use only DigiPageJr series paging stations with DigiPageJr and
only DigiPage series paging stations with DigiPage.