ADTRAN Cable T1 ESF CSU ACE User Manual
Page 43

Chapter 4. Operation
61202066L1-1B
T1 ESF CSU Rackmount User Manual
43
Figure 4-14. DATAMATE Status Menu Tree
(*YES, -NO)
NI RXAIS *
Figure 4-15. DATAMATE Status Display Example
Performance Monitoring statistics for either the local or the remote Tl ESF
CSU RM can be viewed on the DATAMATE or displayed on a CRT
screen via the terminal interface for the SMART 16 shelf.
The parameters available in the performance monitoring reports are:
•
%AV
percent available seconds
•
%EF
percent error-free seconds
•
ES
errored seconds
•
UAS unavailable
seconds
•
SES
severely errored seconds
•
BES
Bursty errored seconds
•
LOFC
loss of frame count.
1 = CLEAR HISTORY
2 = CURR/ALM
1 = STATUS
3 = ERR/ALM HIST
4 = RESET LOC PERF
5 = VIEW LOC PERF
In the status displays above, NI means network interface
and TI means terminal or DTE interface. In the DATA-
MATE status display example above, the first line indicates
that an asterisk (*) means Yes and a dash (-) means No. The
second line lists the applicable interface alarm in question.
The last field is the state of the error/alarm.