9.
Remove clamp ring screws (370B) and lock
washers (136A) (Fig. F).
s
!
WARNING
Use non-magnetic socket and speed wrench to
avoid personal injury or damage to parts.
10. Remove clamp ring (141C) and containment shell
(750) simultaneously (Fig. F).
11. Remove O-ring (412M) and discard (Fig. F).
12. Orient frame adapter assembly in vertical position
and support on blocks (Fig. G).
NOTE: Place a folded clean cloth or cardboard
under frame adapter assembly to soften impact of
driven magnet assembly (740A) on work surface.
Shaft and magnet assembly should rest on work
surface.
13. Remove impeller (101) (Fig. H).
NOTE: It may be necessary to use a puller. Puller
must be placed under vanes so as not to damage
the impeller.
14. Press driven shaft (122A) out until it disengages
(Fig. I).
NOTE: Light tapping with a non-metallic
hammer may be necessary to disengage shaft.
3296 M Group 6/05
31
- 3100 - IOM (52 pages)
- 3171 - IOM (60 pages)
- 3180-86 - IOM (158 pages)
- 3189 - IOM (32 pages)
- 3196 - IOM (148 pages)
- 3196 i-FRAME - IOM (152 pages)
- 3198 i-FRAME - IOM (126 pages)
- 3296 EZMAG - IOM (96 pages)
- 3298 - IOM (120 pages)
- 3311 - IOM (44 pages)
- 3316 - IOM (36 pages)
- 3335 - IOM (40 pages)
- 3355 - IOM (66 pages)
- 3393 - IOM (124 pages)
- 3408 - IOM (78 pages)
- 3408A - IOM (44 pages)
- 3409 - IOM (68 pages)
- 3410 - IOM (56 pages)
- 3420 - IOM (120 pages)
- 3498 - IOM (59 pages)
- 3500XD - IOM (44 pages)
- 3501 Mixer - IOM (48 pages)
- 3600 - IOM (110 pages)
- 3610 - IOM (98 pages)
- 3620 - IOM (98 pages)
- 3640 - IOM (98 pages)
- 3642 - IOM (12 pages)
- 3675 - IOM (12 pages)
- 3700 - IOM (110 pages)
- 3755 - IOM (32 pages)
- 3796 i-FRAME - IOM (134 pages)
- 3910 11th ed. - IOM (80 pages)
- 3935 - IOM (24 pages)
- 3996 - IOM (52 pages)
- 4550 - IOM (36 pages)
- 5000 - IOM (24 pages)
- 5100 - IOM (28 pages)
- 5150 - IOM (28 pages)
- 7200CB - IOM (132 pages)
- ANSI FAMILY IOM (ATEX Compliant) (56 pages)
- ANSI FAMILY IOM (ATEX Compliant) (27 pages)
- ANSI FAMILY IOM (ATEX Compliant) (42 pages)
- ANSI FAMILY IOM (ATEX Compliant) (45 pages)
- Pump Safety (9 pages)