Table 7
Torque Values for Case Mounting
Hex Cap Screws and Nuts
Pump Sizes
Torque (ft. - lb.)
1 x 1
1
2
-6
20
2 x 3-6
20
1 x 1
1
2
-8
59
2 x 3-8
59
1 x 2-10
59
2 x 3-10
59
POST ASSEMBLY CHECKS
After completion of these operations, check if it is possible to rotate shaft easily by hand. If all is proper, continue
with pump start-up.
ASSEMBLY TROUBLESHOOTING
34
3100 IOM 1/97
Symptom
Cause
Remedy
Excessive frame adapter runout.
Corrosion.
Replace frame adapter.
Excessive seal chamber runout.
Seal chamber not properly seated
in frame adapter.
Reseat seal chamber.
Corrosion or wear.
Replace seal chamber/stuffing box
cover.
See also other documents in the category Goulds Pumps Pumps:
- 3171 - IOM (60 pages)
- 3180-86 - IOM (158 pages)
- 3189 - IOM (32 pages)
- 3196 - IOM (148 pages)
- 3196 i-FRAME - IOM (152 pages)
- 3198 i-FRAME - IOM (126 pages)
- 3296 EZMAG - IOM (96 pages)
- 3296M - IOM (92 pages)
- 3298 - IOM (120 pages)
- 3311 - IOM (44 pages)
- 3316 - IOM (36 pages)
- 3335 - IOM (40 pages)
- 3355 - IOM (66 pages)
- 3393 - IOM (124 pages)
- 3408 - IOM (78 pages)
- 3408A - IOM (44 pages)
- 3409 - IOM (68 pages)
- 3410 - IOM (56 pages)
- 3420 - IOM (120 pages)
- 3498 - IOM (59 pages)
- 3500XD - IOM (44 pages)
- 3501 Mixer - IOM (48 pages)
- 3600 - IOM (110 pages)
- 3610 - IOM (98 pages)
- 3620 - IOM (98 pages)
- 3640 - IOM (98 pages)
- 3642 - IOM (12 pages)
- 3675 - IOM (12 pages)
- 3700 - IOM (110 pages)
- 3755 - IOM (32 pages)
- 3796 i-FRAME - IOM (134 pages)
- 3910 11th ed. - IOM (80 pages)
- 3935 - IOM (24 pages)
- 3996 - IOM (52 pages)
- 4550 - IOM (36 pages)
- 5000 - IOM (24 pages)
- 5100 - IOM (28 pages)
- 5150 - IOM (28 pages)
- 7200CB - IOM (132 pages)
- ANSI FAMILY IOM (ATEX Compliant) (56 pages)
- ANSI FAMILY IOM (ATEX Compliant) (27 pages)
- ANSI FAMILY IOM (ATEX Compliant) (42 pages)
- ANSI FAMILY IOM (ATEX Compliant) (45 pages)
- Pump Safety (9 pages)