14. Remove mechanical seal (383).

NOTE: For complete pump disassembly,
continue with removal of seal
chamber/adapter.

REMOVAL OF SEAL CHAMBER/ ADAPTER-
S GROUP (1 x 1

1

2

- 6, 1 x 1

1

2

- 8, 2 x 3 - 6)

15. Remove motor-mounting hex cap screws

(370U) (Fig. 15).

16. Remove seal chamber/adapter (184)(Fig. 16).

!

CAUTION

Be careful not to damage stationary portion of
the mechanical seal.

17. If required, remove mechanical seal stationary

seat.

REMOVAL OF SEAL CHAMBER - M GROUP
(2 x 3-8, 1 x 2-10, 2 x 3-10)

18. Remove seal chamber hex cap screws (370B).

19. Remove seal chamber(184) (Fig. 17).

!

CAUTION

Be careful not to damage stationary portion of
the mechanical seal.

3100 IOM 1/97

27

6

Fig. 14

Fig. 15

Fig. 16

Fig. 17