beautypg.com

Table 3 diametrical wear ring clearance – Goulds Pumps 3100 - IOM User Manual

Page 37

background image

3100 IOM 1/97

29

6

Table 3

Diametrical Wear Ring Clearance

Group

Size

LOCATION

Impeller to Casing in. (mm)

Impeller to Seal Chamber in. (mm)

New

Replace

New

Replace

S

1 x 1

1

2

-6

.017-.021

(.43-.53)

.034 (.86)

N/A

N/A

2 x 3-6

.027-.031

(.69-.79)

.054 (1.37)

N/A

N/A

1 x 1

1

2

-8

.017-.021

(.43-.53)

.034 (.86)

.018-.022

(.46-.56)

.036 (.91)

M

2 x 3-8

.032-.036

(.81-.91)

.064 (1.63)

.024-.028

(.61-.71)

.048 (1.22)

1 x 2-10

.017-.021

(.43-.53)

.034 (.86)

.019-.023

(.48-.58)

.038 (.97)

2 x 3-10

.032-.036

(.81-.91)

.064 (1.63)

.024-.028

(.61-.71)

.048 (1.22)

Fig. 20