Vaddio PresenterPOD System User Manual
Page 5
PresenterPOD System
PresenterPOD System
●
Document Number 342-0212 Rev. B
Page 5 of 12
The PresenterPOD Interface -
Single PresenterPOD System (no scale)
1) Power LED: Blue LED power indicator light
2) Power Jack: 5.5mm OD x 2.5mm ID, Positive Center
3) Recessed Button (for future use - not currently used)
4) POD 1 RJ-45 Jack: Supplies power to the PresenterPOD and exchanges data between POD and Interface.
The Interface can support two PresenterPODs with Cat-5e cables at a distance of up to 100’ (30.48m) each.
5) POD 1 Trigger Outs (short to ground): The icons for triggers are arranged in the same shape as the
buttons on the PresenterPOD.
a. 5a is the large round button on the left side of the PresenterPOD
b. 5b is the center, small and square button which can be used as a PIP on/off for AutoPresenter or as an
ordinary trigger. Default for this button is momentary for PIP on/off, but can be changed to latching.
c. 5c is the large round button on the right side of the PresenterPOD
d. 5d is a dual purpose button. It serves as a Logo button, is back-lit blue while the power is on and it can
be used as a trigger that turns red when triggered.
e. Two ground pins on the Interface (for ease of wiring)
6) POD 2 RJ-45 Jack: Supplies power to the PresenterPOD and exchanges data between POD and Interface
at a distance of up to 100’ (30.48m) each.
7) POD 2 Trigger Outs (short to ground): Same controls, button pushes and icons as POD 1
8) Trigger Settings: The trigger outs can be assigned as latching or momentary triggers (see table below).
Note:
Dip switch 9 combines the PODs logic together and supply up to 8 triggers out (one at a time) using two
pods. With dip switch 9 up, the PODs act independently allowing two triggers at a time to separate input devices.
Dip Switch
DOWN Function
UP Function
SW1
POD 1 - SW1 Latching Trigger (default)
POD 1 - SW1 Momentary Trigger
SW2
POD 1 - SW2 Latching Trigger
POD 1 - SW2 Momentary Trigger (default)
SW3
POD 1 - SW3 Latching Trigger (default)
POD 1 - SW3 Momentary Trigger
SW4
POD 1 - SW4 Latching Trigger (default)
POD 1 - SW4 Momentary Trigger
SW5
POD 2 - SW1 Latching Trigger (default)
POD 2 - SW1 Momentary Trigger
SW6
POD 2 - SW2 Latching Trigger
POD 2 - SW2 Momentary Trigger (default)
SW7
POD 2 - SW3 Latching Trigger (default)
POD 2 - SW3 Momentary Trigger
SW8
POD 2 - SW4 Latching Trigger (default)
POD 2 - SW4 Momentary Trigger
SW9
Logic Combined - 8 Triggers on 2 PODs (default)
Logic - PODS behave independently
SW10
N/A - Future Functionality (default)
N/A - Future Functionality
➏
➐
➑
➊
➋
➌
➍
➎
5a
5b
5c
5d
5e
5b
5a
5c
5d
Cat-5e Cable
PresenterPOD 1
(no scale): Buttons
marked to correspond to the icons on
the Trigger Outs of PresenterPOD 1.
The PresenterPOD is connected to the
POD 1 Interface with a Cat-5e cable
(up to 100’ /30.48m).