Maintenance – Pulsafeeder Chem-Tech Series XP TIMER EN User Manual
Page 11

REV. A PN J63143
- 11 -
5.2. General
DANGER:
DO NOT ATTEMPT TO FEED CHEMICALS WITHOUT FIRST
CONSULTING YOUR CHEMICAL FEEDER DEALER OR CHEMICAL
SUPPLIER. To avoid running out of chemical, follow a regular schedule of
monitoring chemical supply.
CAUTION: Inspect peristaltic tubing frequently and replace when deterioration
becomes apparent. Peristaltic tubing will eventually wear and break if neglected.
This occurrence will cause chemical spillage and a potential for personal injury or
damage to equipment. Always refer to chemical manufacturers
recommendations with regards to safety and handling of hazardous or corrosive
chemicals. Always wear protective clothing and safety glasses when working
near chemical feed systems.
WARNING:
Do not expose the pump or tubing to pressure exceeding the
pressure rating on the pump nameplate.
1) Make sure the mode selector switch is in the off position...
2) Fill the chemical tank with the chemical to be fed.
3) Slide the model selector switch all the way to the left in the on position and
make sure the programming selector switch is in the run position
6. Maintenance
NOTE : To get actual feed rates for specific settings, the output must be verified
by measuring the volume output. Use the flow chart Figure #6, as a guide. To
get the actual feed rate for specific settings, each pump must be calibrated for its
flow. As with any peristaltic pump output varies tubing condition. It is
recommended that feed rates be verified at every tubing change and after every
250-hour. More critical applications require more frequent verification.
NOTE: NO USER SERVICEABLE COMPONENTS ARE INSIDE THE
ENCLOSURE. IF THE POWER SUPPLY CORD BECOMES DAMAGED, IT
MUST BE REPLACED BY PULSAFEEDER, ITS REPRESENTATIVE, OR A
SIMILARLY QUALIFIED TECHNICIAN IN ORDER TO AVOID A HAZARD.