Figures D and E show two

PULSA pumps supplied with

typical piping arrangements

automatic controls, either

for performing pump

pneumatic or electronic, are

calibration. It is desirable to

accompanied by separate

calibrate from the suction side

instructions on output

of the pump so the pump will

adjustment and calibration.

be operating under actual or
comparable discharge
conditions.

Check the capacity several
times at three different stroke
length settings and record
them on linear graph paper.
For all stable conditions,
these points should describe
a straight line.