Lubricating Instructions

month interval check the

and then start up in

PULSAlube is a custom blend

outlet check valves. These

instructions in this

oil with additives for lubrication

items along with oil seal

manual.

and hydraulic transfer service.

inspection should be part of a

(For emergency

routine service procedure.

Long Term

requirements, a list of
acceptable commercial oils is

Oil Capacity

For storage longer than 12

available). The diaphragm on

months in addition to the

the cover of the gear box

The standard 680C metering

above, the following

assembly generally protects

pump requires approximately

procedures should be

the oil from contamination for

one quart of PULSAlube oil to

followed.

extended periods of time. A

fill both chambers and prime

periodic six month check

hydraulic pump head.

1.

Every 12 months

should be made for oil level

PULSAlube oil is available in

PULSAlube oil should be

and possible contamination.

one gallon cans, cartons of six

drained from the gearbox

Under sustained conditions of

gallon cans or 55 gallon

The gearbox and

high humidity or if water is

drums.

hydraulic reservoir

present, the oil can become

should be flushed with

emulsified and take on a

STORAGE INSTRUCTIONS

kerosene or petroleum

yellowish color. Change the

Short Term

base solvent, thoroughly

oil immediately if this occurs

dried out with a rag, and

and examine the make-up

Storage of PULSA Series

then refilled with fresh

valve and other parts for

pump for up to 12 months

PULSAlube oil.

corrosion. A suction pump

after shipment is considered

2.

Every 12 months the

similar to a grease gun is

short term. Under this

motor should be

useful for removing oil from

condition the recommended

connected to a power

chambers, or it may be

storage procedures are as

source and the pump

drained from the ports at the

follows:

operated for a minimum

side of each chamber.

of one hour. It is not

To establish a maintenance

piston be manually

warranty after extended

record and routine procedure,

cycled through 3-6

storage the refurbishment and

check lubricant and drive

cycles every 6 months.

equipment inspection must be

mechanism at three and six

5.

Prior to start-up, perform

done by a Pulsafeeder

month intervals. At the first six

a complete inspection

serviceman.

condition of the inlet and

accordance with

(6) one gallon cans, five

and hydraulic reservoir.

1.

The pump should be

necessary to have liquid

stored indoors at room

in the reagent head

temperature in a dry

during this operation but

environment.

the suction and

2.

The pump gearbox and

discharge ports must be

hydraulic reservoir is to

open to atmosphere.

be completely filled with
PULSAlube oil within two

After 12 months storage

months after date of

Pulsafeeder's warranty

shipment.

cannot cover such items as oil

3.

The gearbox and

seals, gaskets, piston cups

hydraulic reservoir

and other items which are

should be inspected

subject to deterioration with

every 3-6 months.

age. If the pump has been in

Maintain the oil level and

storage for longer than 12

assure that no water or

months it is recommended

condensation is present,

that these items be replaced

follow Procedure II, Step

prior to going into service.

A below.

Material and labor to

4.

It is recommended that

recondition or replace this

the stroke length of the

class of item is the

pump be adjusted to its

purchaser's responsibility.

midpoint and that the

For a one year service