beautypg.com

Pulsafeeder Pulsa Series 200-680C User Manual

Page 2

background image

2

Figure 1.

Table of Contents

How it Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Installation Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Start-Up Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Operation and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Storage Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Hydracone Diaphragm
Figure 2

The HYDRACONE elastomer
diaphragm Figure No. 2
isolates product pumped from
the plunger and pump
mechanism.

Several elastomers are
offered including Viton and

*

Hypalon which provide a

*

satisfactory chemical
resistance for a wide variety of
corrosive fluids.

How it Works:

Figure 1

A standard foot mounted
motor drives a wormshaft at
constant speed. Through
wormgear reduction and
eccentric, a reciprocating
power stroke is transferred to
a plunger. The length of
plunger

A special property petroleum oil
tradenamed "PULSAlube" is generally
used as hydraulic fluid. Continual
reference to "oil" as hydraulic medium
implies its

stroke determines pump

The forward movement of the

capacity and can be adjusted

plunger pressurizes the

manually to provide pumping

hydraulic fluid which expands

range from 0-100% of rating.

the elastomer HYDRACONE

However, this plunger does

diaphragm in direct relation to

not pump chemicals, but an

plunger travel. As diaphragm

exceptionally stable oil having

expands, chemical is forced

*

excellent lubricating qualities.

from reagent head and out

This makes a perfect

discharge check valve. When

pumping medium.

plunger starts to return, the

general use rather than its use of
necessity. Check with your
representative or the factory if
substitute oils must be used.

hydraulic pressure is released
and HYDRACONE returns to
normal shape. This
diaphragm return, which is not
affected by inlet pressure
conditions, draws in new
chemical under high suction
lift.

*Products of E.I. DuPont