Calibration – Pulsafeeder Pulsa Series 200-680C User Manual

Page 7

background image

7

Figure B

To Adjust Flow Rate;

Calibration:

This is caused by

Figure B.

The 680C PULSA pumps are

at room temperature with 7

Capacity at atmospheric

provided with a micrometer

foot flooded head at full rated

pressure will be nearly that of

knob adjustment for changing

pressure. Any curves

calculated displacement. As

length of stroke while in

supplied by Pulsafeeder

the discharge pressure

operation or idle. NOTE: The

would be representative of

increases there will be a

external auto locking knob

this test and can only be used

corresponding decrease in

must be fully disengaged prior

as a guideline.

capacity at a rate of

to adjustment. When

approximately 1% per 100 psi

adjustment is complete the

All pumps must be calibrated

increase.

lock will automatically engage

under actual operating

to prevent drifting of the

conditions for the operator to

stroke setting. Turn

know the proper adjustment

adjustment knob clockwise to

for particular outputs. A

increase flow and

typical displacement chart is

counterclockwise to decrease

shown in Figure C. Note that

flow. The adjustment knob is

output is linear with respect to

read directly in percent of

micrometer settings but that

stroke length. These

increase in discharge

indications can be converted

pressure decreases output

to volumetric or weight units

slightly and describes the line

by calibration conversion

parallel to that at atmospheric

charts.

pressure.

All pumps are tested on water

and valve inefficiencies.

compression of hydraulic oil