4. Standard Terminal Block Layout

1 1 1
0 1 2

1 1
6 5

1 1
3 4

4 8 9 6 7 5

2 3

1

FIGURE 2

Refer to figure 2, above:

1. Internal terminal blocks (gray)

2. Motor armature & motor field connections (black)

3. Tachometer feedback connections (orange)

4. Drive in remote mode N.O. output (green)

5. Drive running N.O. output (green)

6. System fault N.O. output (green)

7. High temperature N.O. output (green)

8. Drive start input (yellow)

9. External system fault (red)

10. N.C. high temperature fault input (red)

11. N.O. high discharge pressure fault input (red)

12. N.O. leak detected fault input (red)

13. 4-20mA speed reference input (blue)

14. 4-20mA speed reference output (blue)

15. 4-20mA stroke reference input (blue)

16. 4-20mA stroke reference output (blue)

N.O. = normally open

N.C. = normally closed