7. Drive

Specifications

The Cruise Control

comes standard with a Control Techniques Focus 3

DC Drive. The panel documentation

includes the complete User Manual from Control Techniques. Included below are general specifications for this
DC drive and control panel system.

These specifications are applicable only to the Focus 3

drive, if your panel has been specified with an

alternate DC SCR drive, please refer to the appropriate manufacturer’s literature supplied with your
panel system.

7.1 General:

Control Panel Degree of Protection:

Enclosure and disconnect - NEMA 4X

Percent

Speed/Stroke

Meter

-

IP65

7.2 DC-SCR

Drive:

Input Voltage:

120VAC / 240VAC +/- 10%

HP

Range:

1/4

to

1

HP

@

120VAC,

1/2 to 2 HP @ 240VAC

Armature Voltage Range:

90VDC or 180VDC

Speed Regulation (95% load change):

Armature feedback: 1% max. speed
Tach feedback: 0.5% max. speed

Tachometer Voltage @ maximum speed:

Low Range - 6.5 to 17.4 VDC
High Range - 60 to 160 VDC

Overload Capacity:

150% of max. rating for 1 minute

Maximum Speed:

80-120% of rated speed

Minimum Speed:

0-20% of rated voltage

IR Compensation:

0-20% of rated voltage

Current

Limit:

0-150%

of

selected

range

Acceleration/Deceleration:

0.3 - 20 seconds (linear)

7.3 Signal

Inputs:

Drive Start Input:

Remote dry contact, close to run [standard]
Remote 120VAC input, energize to run [option]
Remote 24VDC input, energize to run [option]

Motor Thermal Fault:

N.C. input, opens under fault condition

High Discharge Pressure Fault:

N.O. input, closes under fault condition

PULSAlarm Diaphragm Leak Fault:

N.O. input, closes under fault condition

Chemalarm Diaphragm Leak Fault:

External probe, 24VDC from Chemalarm

circuit

Analog

Inputs:

4-20mA

50Ω impedance

7.4 Signal

Outputs

System Fault:

N.O. closes under fault condition
5A @ 240 VAC maximum

Drive Running Status:

N.O. closes when running,
5A @ 240 VAC maximum

Drive in Remote:

N.O. closes when "Drive Start" is in remote
3A @ 120 VAC, 1.5A @ 230 VAC maximum

Analog Outputs:

Percent Speed/Stoke meters only:
4-20mA, 500Ω, short circuit protection