10. Elapsed Time Meters
The Elapsed Time Meters are configured and programmed for your application
during assembly. The following information is for reference only:
• Elapsed Timer Setup
The setup switches for this elapsed timer are located at the bottom of the meter inside the enclosure. Switch
number 1 is located on the side under the reset button, and switch number 2 is located on the other side.
• Time-range Switch (2)
Set this switch towards the terminal block (back of device) for 0.1 hour resolution. The displayed range will
be from 0.0h to 999999.9h.
Default setting is 0.0h to 3999d23.9h. (Note, h=hours, d=days).
• Key-protect Switch (1)
Set this switch towards the terminal block (back of device) to prevent the front reset button from resetting the
counter.
• Replacement Components
The part number from Omron
™
to order for a replacement battery for this meter is Y92S-36.
• Note
Please remove all control wiring before replacing or servicing the battery or any components within these
meters.