Functional programming, Percent speed meter programming value tables, Percent stroke meter programming values – Pulsafeeder Pulsa Series Cruise Control User Manual
Page 18
9.2.2 Functional
Programming
1. Press and hold the
S
key; then press the ▼ key. Release both immediately when display shows
PAS
.
2. If the password is not 0 (zero), use the ▲ or ▼ keys to select the proper password. Press
S
to enter
and move to the next parameter. All meters are shipped with the password set to 0 (zero).
3. At each parameter, the display will show the parameters for two seconds, then display the value
associated with the given parameter. Use the ▲ and ▼ keys to modify the value and press
S
to move
to the next parameter. If no changes are required, press
S
to retain the current value and move to the
next parameter.
4. Set the Input Range (HiE, LOE) and Display Range (Hi, LO) and press
S
until
END
is displayed.
5. The system automatically returns to the run mode.
9.2.3
Percent Speed Meter Programming Value Tables
Description Display
Value
Input range selection
-
4
Decimal Point Location
dP
111.1
High limit for electrical input range*
HiE
90.0 (90 VDC armature) 180.0 (180 VDC armature)
Low limit for electrical input range
LOE
0.0
Display value corresponding to HiE
Hi
100.0
Display value corresponding to LOE
LO
0.0
*HiE is set at tachometer voltage at maximum motor speed if tachometer feedback is used.
9.2.4
Percent Stroke Meter Programming Values
Description Display
Value
Input range selection
-
4
Decimal Point Location
dP
111.1
High limit for electrical input range
HiE
20.0
Low limit for electrical input range
LOE
4.0
Display value corresponding to HiE
Hi
100.0
Display value corresponding to LO
LO
0.0
14