9.2.2 Functional

Programming

1. Press and hold the

S

key; then press the ▼ key. Release both immediately when display shows

PAS

.

2. If the password is not 0 (zero), use the ▲ or ▼ keys to select the proper password. Press

S

to enter

and move to the next parameter. All meters are shipped with the password set to 0 (zero).

3. At each parameter, the display will show the parameters for two seconds, then display the value

associated with the given parameter. Use the ▲ and ▼ keys to modify the value and press

S

to move

to the next parameter. If no changes are required, press

S

to retain the current value and move to the

next parameter.

4. Set the Input Range (HiE, LOE) and Display Range (Hi, LO) and press

S

until

END

is displayed.

5. The system automatically returns to the run mode.

9.2.3

Percent Speed Meter Programming Value Tables


Description Display

Value

Input range selection

-

4

Decimal Point Location

dP

111.1

High limit for electrical input range*

HiE

90.0 (90 VDC armature) 180.0 (180 VDC armature)

Low limit for electrical input range

LOE

0.0

Display value corresponding to HiE

Hi

100.0

Display value corresponding to LOE

LO

0.0


*HiE is set at tachometer voltage at maximum motor speed if tachometer feedback is used.

9.2.4

Percent Stroke Meter Programming Values


Description Display

Value

Input range selection

-

4

Decimal Point Location

dP

111.1

High limit for electrical input range

HiE

20.0

Low limit for electrical input range

LOE

4.0

Display value corresponding to HiE

Hi

100.0

Display value corresponding to LO

LO

0.0