Motor High Temp Fault Amber Pilot Light

Illuminates when the motor experiences a thermal overload or high temperature condition. This will also
cause the appropriate relay to latch, and the pump will stop. This light will not go off until the fault condition
is removed and the Fault Reset pushbutton is depressed. This fault will also signal the System Fault light.


High Discharge Pressure Amber Pilot Light

Illuminates when the system experiences a high discharge pressure condition. This will also cause the
appropriate relay to latch, and the pump will stop. This light will not go off until the fault condition is
removed and the Fault Reset pushbutton is depressed. This fault will also signal the System Fault light.


Fault Reset Black Pushbutton, Momentary

This button resets the System Fault and any other fault conditions. See above section on System Fault.
Note that the fault reset pushbutton will function only if the fault condition has been corrected.


Power On White Pilot Light

This light will illuminate when the system has 120-volt control power. If this light is not on, the system is not
powered and the controls will not operate predictably. Check the system disconnect, if available, or the main
power into the panel. If the system has main power above 120VAC, check the fusing at the transformer as
well.