beautypg.com

Operation – Pitco Frialator SRTG14-2 Dual Gas Rethermalizer User Manual

Page 20

background image

OPERATION

16

L20-291, rev. 1 (05/11)

Tank Capacity

Model

Capacity

SRTG

17-1/2 Gal.

(66.2 Liters)

2.2. FILLING THE APPLIANCE

2.2.1. FILLING THE COOKER TANK
It is recommended that the cooker tank is filled with hot water. This will greatly decrease the time
it takes for the appliance to reach operating temperature. Refer to the following procedure to fill
the cook tank prior to operation.

1. Ensure that the drain valve is closed.

2. Fill the tank with water until the water reaches the water level line(s).

3. This appliance is equipped with an automatic water level maintaining system. To fill the

tank with water, Press the unit’s I/0 (ON/OFF) switch to the I (ON) position. This will cause
the tank to fill with water. The tank will continue to fill until the water level reaches the level
sensors. When both of the active water level sensors are covered the solenoid valve will
close stopping the flow of water. During normal operation the automatic fill system will
maintain the water level at the proper height.

NOTE: If the water control system turns on while the main burners are running, the main
burners will turn off. This is Normal and will not affect the operation of the appliance. When the
tank refills to the high level probe, the main burners will relight.

2.2.2. FILLING THE COOKER TANK WITHOUT THE AUTOMATIC LEVEL SYSTEM
Although the water fill system is completely automatic, the tank can be filled without putting the
appliance into full operational mode. To fill the tank without operating the appliance press the
rocker switch to the

symbol. Continue to hold down the switch until the appliance is

completely filled.

DRAIN VALVE CLOSED

CAUTION

This appliance is not designed for cooking with oil. Fill with potable water only.

WARNING

Water must completely cover the heat tubes at all times while appliance is on.

This manual is related to the following products: