SRTG: Gas Floor Model Rethermalizer
OPERATION
15
1. Cook
Tank
2. Controller
(Not on all Models)
Controls the water temperature inside the cook tank.
Optional timers are located on the controller (if equipped).
If the controller has an ON/OFF button, it will be used to turn ON the controller as well as other
features on the appliance.
3. Door
(Shown Open)
Provides access to the drain valve handle, high temperature reset button and gas valve, pilot,
burners and shutoff valves.
4. Drain Valve Handle (Shown in the closed position)
Opens the drain valve so water can be drained from the cook tank.
The drain valve interlock feature will stop the appliance from heating if the drain valve is opened.
5. Drain
Outlet
Water exits the cook tank through the drain outlet when draining or overflowing.
6. Overflow
Line
When the cook tank water level reaches the overflow, water will flow unobstructed through the
overflow line and eventually exit the appliance through the drain outlet.
7. High Temperature Reset Button
This button may need to be pressed in the event that the high temperature limit has tripped.
8. Tank
Cover
(shown in UP position)
Keeps heat inside and debris outside of the cook tank.
9. Tank Cover Latch
Holds the tank cover in the up position when adding or removing product from the cook tank.
10. ON/OFF Switch
Turns the appliance ON and OFF. Some controllers require that they are turned ON by another
button after the ON/OFF switch is in the ON position.
11. Fill Bypass Switch
When this switch is held down the cook tank will fill with water regardless of the water level.
12. Gas Shutoff Valve
Shuts off the supply of gas to the gas valve.
13. Gas Valve
Controls the flow of gas to the pilot and burners.
14. Pilot
The pilot lights the burners when the water in the cook tank requires more heat.
15. Burners
Heats the water inside the cook tank.
16. Main Water Shutoff Valve
Shuts off the water supply to all tanks inside the cabinet.
17. Tank Water Shutoff Valve
Shuts off the water supply to the closest tank.
18. Solenoid Water Valve
Turns the supply of water to the tank ON and OFF.
This valve is controller by the water level sensors inside the tank.
Valve can also be controlled by the fill bypass switch.