Troubleshooting, Accessories, Ec declaration of conformity – Karcher HKS 100 LM User Manual
Page 26: Warranty
-
12
We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements of the
EU Directives, both in its basic design and
construction as well as in the version put
into circulation by us. This declaration shall
cease to be valid if the machine is modified
without our prior approval.
5.957-455
The undersigned act on behalf and under
the power of attorney of the company man-
agement.
Authorised Documentation Representative
S. Reiser
Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2013/12/01
The warranty terms published by our com-
petent sales company are applicable in
each country. We will repair potential fail-
ures of the appliance within the warranty
period free of charge, provided that such
failure is caused by faulty material or de-
fects in fabrication.
Troubleshooting
Fault
Possible cause
Remedy
of whom
The interior cleaner does
not turn or only turn partial-
ly or abruptly
The speed is set too low.
Adjust higher speed on the regulator screw.
Operator
The pressure of the cleaning
agent is too low or the wrong noz-
zles have been installed on the in-
terior cleaner.
Adjust the nozzles on the interior cleaner to the
feed flow of the high-pressure pump (smaller
nozzle opening means higher pressure).
Operator
Air in the reguator fluid.
Replace regulator fluid (see Maintenance Pro-
cedures).
Operator
Wrong regulator fluid has been
used.
Replace the regulator fluid completely.
Customer Service
The seals on the shafts are leak-
ing.
Replace washers.
Customer Service
Bevel wheels dirty.
Clean bevel wheels (see Maintenance Proce-
dures).
Operator
Uneven cleaning jet
Spray nozzles clogged.
Clean spray nozzles.
Operator
Spray nozzles damaged.
Replace spray nozzles.
Operator
Accessories
Description
Order No.
Parts kit for frame
on request
Cover with frame
on request
Swivel frame
on request
High-pressure connection
bow 90°, M22x1.5
4.408-023
Regulator fluid for normal
operation - cold/warm run
0.25 liters
6.288-021
Regulator fluid for normal
operation - cold run 0.25
liters
4.070-020
Regulator fluid for food op-
erations - cold run 0.25 lit-
ers
4.070-033
Regulator fluid for food op-
erations - cold run 1 liters
4.070-047
Regulator fluid for solvent
operations - cold run 1 liter
6.288-007
EC Declaration of Conformity
Product:
Internal cleaner
Type:
HKS 100
Relevant EU Directives
2006/42/EC (+2009/127/EC)
94/9/EC
Applied harmonized standards
EN ISO 12100
EN 1127-1: 2011
EN 13463-1: 2009
EN 13463-5: 2011
Applied national standards
-
ID no. of notified body
0123
TÜV SÜD
Ridlerstr. 65
80339 München
Test report no.
Ex5 0307 10088 097
Marking
II 1 G D c T4
CEO
Head of Approbation
Warranty
26
EN