elektraLite MY 250I User Manual
Page 15
14
With this function you can adjust the lamp via the Control Board. The shutter opens and the lamp can be
adjusted. In this mode, the device will not react to any control signal.
1. Select
“LADJ” by pressing [UP] button.
2. Press
[ENTER], the display shows “ON” or “OFF”.
3. Press
[UP] to select “ON” if you wish to enable this function or “OFF” if you don’t.
4. Press
[ENTER] to confirm.
5. Press
[EXIT/DN] in order to return to the main menu.
- Test function of each channel
With this function you can test each channel on its (correct) function.
1. Select
“tESt” by pressing [UP] button.
2. Press
[ENTER], the display shows “T-XX”, “X” stands for the channel number.
3.
The current channel will be tested.
4.
Select the desired channel by pressing
[UP] button.
5. Press
[ENTER] or [EXIT/DN] to exit.
- Main menu 4
1. Press
[ENTER] for 3 seconds to enter the main menu (display flashing).
2. Press
[UP] to select “TIME”.
- Fixture running time
This function displays the running time of
MY 250Ì.
1. Select
“MATI” by pressing [UP] button.
2. Press
[ENTER], the display shows “XXXX”, “X“ stands for the number of hours.
3. Press
[ENTER] or [EXIT/DN] to exit.
- Lamp running time
This function displays the running time of the lamp.
1. Select
“LATI” by pressing [UP] button.
2. Press
[ENTER], the display shows “XXXX”, “X“ stands for the number of hours.
3. Press
[ENTER] or [EXIT/DN] to exit.
- Clear fixture time
This function clears the running time of the device.
1. Select
“CLMT” by pressing [UP] button.
2. Press
[ENTER], the display shows “ON” or “OFF”.
3. Press
[UP] to select “ON” to enable this function or “OFF” if you don’t.
4. Press
[ENTER] to confirm.
5. Press
[EXIT/DN] to return to the main menu.
- Clear lamp time
This function clears the running time of the lamp. Please clear the lamp time every time you replace the