Machine Errors

70444801

38

Moisture Sensor Error

While in Idle Mode and on the Cycle Menu, the

control will begin to monitor the moisture sensor input

after one minute without user input. If the moisture

sensor circuitry detects a load present signal read

consistently (every second) for a ten minute period

without user input, the control will declare, if

programmed to do so, a load sensed. If at any time

during this sensing period, user input is detected or the

control determines that there is no load present, it

resets the load detected counter. After this ten minute

period with a consistent load sensed, the control

queues the Load Sensed Menu to display. When user

interaction is sensed, the display will wake and show

the Load Sensed Menu prompting the user to answer

whether the machine is currently empty. If the operator

selects No, the control returns to the Cycle Menu. If

the operator selects Yes, the control will increment the

Moisture Sensor Error counter and record the error in

the queue of the last eight machine errors and display

the Service Moisture Sensor Menu, instructing the

operator to service the moisture sensor soon and press

the

keypad to return to the Cycle Menu. The

Load Sensed prompt will only appear once a day,

unless machine power is cycled. If the control is idle,

with the Load Sensed Menu queued, and a Service

Schedule Reminder is then queued as well, when

detecting user interaction, the control will first display

the appropriate Service Schedule Menu and then

display the Load Sensed Menu after a key has been

pressed.

Fan Motor Contactor Error

If the control attempts to turn on the heater relay and

the control does not sense that the Fan Motor

Contactor is closed, the control will go to the Cool

Down portion of the cycle, display an error message

and turn on the audio signal. Once the Cool Down

portion of the cycle ends, the control will continue

displaying the error message until power is cycled or
the

keypad is pressed. This error will increment

the Fan Motor Contactor Error counter and will be

saved in the Last Eight Alarms Menu.

Fan Motor Centrifugal Switch Error

If the control attempts to turn on the fan motor and the

fan motor contactor is sensed closed but the Fan Motor

Centrifugal Switch fails to close, the control will go

into the Cool Down portion of the cycle, display an

error message and turn on the audio signal. Once the

Cool Down portion of the cycle ends, the control will

continue displaying the error message until power is
cycled or the

keypad is pressed. This error will

increment the Fan Motor Centrifugal Switch error

counter and will be saved in the Last Eight Alarms

Menu.

DIP Switch/Harness Index Mismatch
Error

On power up the control reads the Temperature Index

Harness value and compares that with the value of

switch 1, switch 2 and switch 3 on the DIP switch

configuration. If the result is an invalid setup the

control will not enter Idle mode and instead enter Error

Mode. The control will ignore all user inputs and

display an error message. The machine must be

powered down and the correct temperature index

harness must be installed and/or the DIP switch

configuration must be corrected.