beautypg.com

Inputs outputs menu – Alliance Laundry Systems TMB1276C User Manual

Page 36

background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Diagnostics

70444801

34

Inputs Outputs Menu

When the Inputs Outputs Menu is accessed through

the Diagnostic Menu, the user can manually turn on

outputs. The user can scroll through the outputs using

any of the arrow keys, the cursor is indicated by

flashing the active output on the screen. The user must
“setup” the outputs to be turned on. The

keypad

is used to select individual outputs to be turned on or
off. After the

keypad is pressed the control will

turn the selected outputs on and display the text

“RUNNING”. The outputs cannot be selected until
the

keypad is pressed. The text “RUNNING” is

no longer displayed. The screen will still show the

selected outputs on the screen and the user can again
select outputs to be turned on or off. If the

or

keypad is pressed at any time during this test,

the control will turn off all outputs if the test is running

or return to the previous screen if the test is not

running.
If the Inputs Outputs Menu is accessed through the
Run Diagnostic Menu (pressing the

keypad

during a running cycle) the menu shows only what is

turned on and off as the cycle runs. Refer to Figure 44.

Abbreviations for the Inputs and Outputs are defined

in the following table:

Table 4

TMB1425R

Figure 44

Inputs Outputs

Outputs:

Intputs:

RPM:25

Moisture:30%

DM

FM FW

RV

HT

EA IR

DR LD AFS FCRS FCLS CL SL1 SL2

IL

RS

DIP1

DIP2 DIP3 DIP4 DIP5 DIP6

DIP7

DIP8

30:29

Temp:180 F

Inputs

DR

Loading Door

LD

Lint Door

AFS

Airflow Switch

FCRS

Fan Motor Contactor Switch

FCLS

Fan Motor Centrifugal Switch

CL

Cabinet High Limit

SL1

Store 1 High Limit

SL2

Store 2 High Limit

IL

Ignition Lockout

RS

Rotation Sensor

DIP1

Dip Switch 1

DIP2

Dip Switch 2

DIP3

Dip Switch 3

DIP4

Dip Switch 4

DIP5

Dip Switch 5

DIP6

Dip Switch 6

DIP7

Dip Switch 7

DIP8

Dip Switch 8

Temp

Temperature

RPM

Rotations per Minute

Moisture

Moisture Level

Outputs

DM

Damper Motor

FM

Fan Motor

FW

Forward Contactor

RV

Reverse Contactor

HT

Heater

EA

External Alarm

IR

Ignition Reset