Operation Modes

General Modes of Operation

In each mode of operation, the user may press keypads

or communicate with the control to change the

displayed menu.

Power-up Mode

The control enters this mode at power-up. After the

control completes operation in the Power-up Mode it

will enter Idle Mode. The display is blank during

Power-up Mode.

Idle Mode

The control is ready for operation in Idle Mode.

Control can display different menus depending on user

input (keypad press, opening or closing the loading

door, or PDA communication). If there is no user input

for one minute, control will turn off the LCD

backlight. The control will light when there is user

input. If there is no user input for 10 minutes, the

display will go blank.
If the control is in Idle Mode, Cycle Menu is
displayed, loading and lint door closed, and the

keypad is pressed, control will enter Run Mode.

Run Mode

The Control enters Run Mode during a cycle. The

Display shows machine cycle time remaining, the

current cycle type, segment, temperature, and

graphical indicators. Loading and lint doors are closed
during Run Mode. Press

keypad to stop cycle

and enter Pause Mode. Press

keypad to enter

Run Diagnostic Menu. Control enters Pause Mode if
loading or lint door opens. Press

to Rapid

Advance.

Rapid Advance Mode

If the Rapid Advance Option is enabled, the user can

advance a running machine cycle by pressing the

keypad. In a Time Dry cycle, pressing the

keypad will decrease the remaining time by one
minute. Pressing and holding the

keypad will

decrease the remaining time by four minutes per

second until the end of the cycle.
In the Auto-Dry and Moisture Dry cycles, pressing the

keypad will advance the cycle to the next

enabled segment. Note that Auto-Dry cycles only have

one programmable segment.

In the Cool Down segment, pressing the

keypad

will decrease the remaining time by one minute.
When the cycle is completed, the audit counter, Total

Rapid Advance Cycles is incremented rather than the

Total Machine Cycles audit counter. In addition this

cycle is recorded in the audit list “Last 25 Machine

Cycles Completed”. If the Rapid Advance Option is

disabled preventing a manual Rapid Advance, the user

may still execute a Rapid Advance using the PDA or

PC. Refer to UniLinc PC and PDA Application User

Instructions for additional information on using a

PDA or PC to Rapid Advance a cycle.

Pause Mode

If

keypad is pressed or the loading or lint door is

opened while in Run Mode, control enters Pause

Mode.
If the door is opened then closed, the control will
prompt the user to press

to resume the cycle.

If

is pressed while already in Pause Mode, the

control will enter End of Cycle Mode.

Error Mode

This mode will be entered to display all fatal machine

errors.

Communication Mode

This mode is entered whenever the control is

communicating with a PDA or a network. Refer to

UniLinc PC and PDA Application User Instructions.

Cool Down Mode

The control enters the Cool Down Mode after the heat

segment of the cycle is completed or fatal error occurs.

The control turns the heater off and for steam heated

units turns the damper motor on. The cool down

segment will end once the cool down temperature has

been reached or the programmed cool down time

expires, which ever happens first.