AT-8000 Series Fast Ethernet Switches Installation Guide

95

12

PLUGGABLE EQUIPMENT, the socket outlet shall be installed near the equipment and
shall be easily accessible.

13

CAUTION: Air vents must not be blocked and must have free access to the room
ambient air for cooling.

14

OPERATING TEMPERATURE: This product is designed for a maximum ambient
temperature of 40° degrees C.

15

ALL COUNTRIES: Install product in accordance with local and National Electrical
Codes.

16

WARNING: As a safety precaution, a 10 Amp circuit breaker should be installed at
the supply end of the cable to be used with this LAN equipment.

Always connect the wiring to the LAN equipment first before connecting the wiring
to the breaker. To avoid the danger of physical injury from electrical shock, do not
work with HOT feeds. Always be sure that the breaker is in the OFF position before
connecting the wiring to the breaker.

17

WARNING: Do not strip more than the recommended amount of wire. Stripping
more than the recommended amount can create a safety hazard by leaving exposed
wire on the terminal block after installation.

18

WARNING: When installing this equipment, always ensure that the frame ground
connection is installed first and disconnected last.

19

CAUTION: “Safety Hazard” Check to see if there are any exposed copper strands
coming from the installed wire. When this installation is done correctly there should
be no exposed copper wire strands extending from the terminal block. Any exposed
wiring can conduct harmful levels of electricity to persons touching the wires.

20

NOTE: This system will work with Positive grounded or Negative
Grounded DC systems.