beautypg.com

Allied Telesis AT-MC303 User Manual

Page 22

background image

12

Note
For additional technical information on the media converter’s fiber optic
port, refer to “Technical Specifications” on page 18.

Table 5 Fiber Optic Port Cabling Specifications - Half-duplex

Model

Cable

Maximum Distance

All models

50/125 or 62.5/125
micron multimode fiber
optic cable

The total distance of all fiber runs cannot
exceed the following limits:

1

With one Media Converter inline:
Switch to Switch = 372 m (1221 ft)
Workstation to Switch = 372 m (1221 ft)
Switch to Class II Repeater = 185 m (607 ft)
Switch to Class I Repeater = 137 m (450 ft)

With two Media Converters inline:
Switch to Switch = 332 m (1089 ft)
Workstation to Switch = 332 m (1089 ft)
Switch to Class II Repeater =145 m (476 ft)
Switch to Class I Repeater = 97 m (318 ft)

1. Each media converter used inline within a single collision domain will reduce the overall segment

length by 40 meters (131.24 feet) of fiber.

This manual is related to the following products: