beautypg.com

Allied Telesis AT-MC104ST/FS3, FS4 User Manual

Page 25

background image

AT-MC104 Series Installation Guide

15

Table 8 Fiber Optic Datalink

Table 9 Fiber Optic Loss Specifications (Benchmarks)

Model

Fiber
Optic

Diameter

(microns)

Optical

Freq.

Min.

Power/

Link

Budget

(dB)

Avg.

Signal

Loss

(dB)

Min.

Distance

Spec.

1

1. The launch power measured at one meter from the transmitter

Max.

Distance

Spec.

(Full-duplex

only)

AT-MC104XL

9/125

1310 nm

16.0

19.50

0

15 km
(9.3 mi)

AT-MC104LH

9/125

1310 nm

30.0

35.00

0

40 km
(24.8 mi)

AT-MC104SC/FS3
and
AT-MC104ST/FS3

9/125

1310 nm

33.0

35.00

15 km
(9.3 mi)

75 km
(46.5 mi)

AT-MC104SC/FS4
and
AT-MC104ST/FS4

9/125

1550 nm

34.0

35.50

40 km
(24.8 mi)

100 km
(62 mi)

Fiber Type

1

1. SMF = Single-mode Fiber

Fiber Optic

Diameter

(microns)

Optical

Frequency

Typical Loss

Factor

(dB/km)

Worst Case
Loss Factor

(dB/km)

SMF

9/125

1310 nm

0.40

1.00

9/125

1550 nm

0.30

0.75