15
Table 8 Fiber Optic Datalink
Table 9 Fiber Optic Loss Specifications (Benchmarks)
Model
Fiber
Optic
Diameter
(microns)
Optical
Freq.
Min.
Power/
Link
Budget
(dB)
Avg.
Signal
Loss
(dB)
Min.
Distance
Spec.
1
1. The launch power measured at one meter from the transmitter
Max.
Distance
Spec.
(Full-duplex
only)
AT-MC104XL
9/125
1310 nm
16.0
19.50
0
15 km
(9.3 mi)
AT-MC104LH
9/125
1310 nm
30.0
35.00
0
40 km
(24.8 mi)
AT-MC104SC/FS3
and
AT-MC104ST/FS3
9/125
1310 nm
33.0
35.00
15 km
(9.3 mi)
75 km
(46.5 mi)
AT-MC104SC/FS4
and
AT-MC104ST/FS4
9/125
1550 nm
34.0
35.50
40 km
(24.8 mi)
100 km
(62 mi)
Fiber Type
1
1. SMF = Single-mode Fiber
Fiber Optic
Diameter
(microns)
Optical
Frequency
Typical Loss
Factor
(dB/km)
Worst Case
Loss Factor
(dB/km)
SMF
9/125
1310 nm
0.40
1.00
9/125
1550 nm
0.30
0.75