Allied Telesis AT-MC104ST/FS3, FS4 User Manual
Page 18

8
Table 5 Single-mode Port Specifications (Half-duplex)
1
1. The total distance of the fiber optic lengths cannot exceed the limits stated in the table. Each media converter
used inline within a single collision domain reduces the overall segment length by 40 m (131 ft).
Note
For additional technical information on the media converter’s fiber optic
ports, refer to “Technical Specifications” on page 13.
Number of Media Converters
Connected Devices
Maximum Distance
One Media Converter Inline
Switch to switch
372 m (1,221 ft)
Workstation to switch
372 m (1,221 ft)
Switch to Class I repeater
137 m (450 ft)
Switch to Class II repeater
185 m (607 ft)
Two Media Converters Inline
Switch to switch
332 m (1,089 ft)
Workstation to switch
322 m (1, 089 ft)
Switch to Class I repeater
97 m (318 ft)
Switch to Class II repeater
145 m (476 ft)