Installation

16

Caution

POE and power cord are used as disconnection devices: To de-energize
equipment, disconnect the POE and the power cord.

5.

There are two ways to power ON the switch; perform one of the following
steps:

Using a wall power adapter: Plug one end of the power cord to the
24VDC power connector on the back of the switch and the other end of
the power cord to a power outlet.

Using the POE port: Plug one end of the twisted pair cable to the POE
port on the back of the switch and the other end of the twisted pair
cable to an Ethernet port on a PSE device.

Note

The AT-FS705PD Switch is classified as IEEE Std 802.3af-2003,
Environment A, where a LAN or LAN segment, with all its associated
interconnected equipment, is entirely contained within a single low-
voltage power distribution system and within a single building.

6.

Verify that either the PWR POE or WALL LED is green. If the LED is
OFF, refer to “Troubleshooting” on page 21 for instructions.

7.

Power ON the end-nodes connected to the switch.

8.

Check the LINK/ACT LEDs for each port is green. If a LED is OFF, refer
to “Troubleshooting” on page 21 for instructions.