Table 4 lists the cabling specifications for the fiber optic port when
operating in full-duplex mode.

Table 5 lists the cabling specifications for the fiber optic port when
operating in half-duplex.

Table 4. 10Base-FL Fiber Optic Cabling Specifications (Full-duplex)

Model

Cable Type

Maximum

Operating

Distance

1

1. Maximum distance for 100 Mbps optical datalinks is dependent on the following

factors: quality of fiber optic, duplex mode of both end-nodes, and maximum opti-
cal loss budget for the optical fiber at each operating optical wavelength.

Maximum

Allowable Loss

Budget

AT-MC13

62.5/125 micron
multimode

2 km (1.2 mi)

20dB at 850 nm

Table 5. 10Base-FL Fiber Optic Cabling Specifications (Half-duplex)

Number of Media

Converters

Connected Devices

Maximum

Operating

Distance

One Media Converter
Inline

Switch to Switch

372 m (1,221 ft)

Workstation to Switch

372 m (1,221 ft)

Switch to Class I
Repeater

137 m (450 ft)

Switch to Class II
Repeater

185 m (607 ft)

Two Media Converters
Inline

Switch to Switch

332 m (1,089 ft)

Workstation to Switch

332 m (1,089 ft)

Switch to Class I
Repeater

97 m (318 ft)

Switch to Class II
Repeater

145 m (476 ft)