beautypg.com

Agency certifications, Fiber optic port specifications – Allied Telesis AT-MC13 User Manual

Page 38

background image

Appendix A: Technical Specifications

38

Agency Certifications

EMI

FCC Part 15 Class B, EN55022 Class B,
VCCI Class B, C-TICK

Immunity

EN55024

Electrical Safety

UL 60950-1 (

C

UL

US

), EN60950-1 (TUV),

CE

Laser Safety

EN60825-1

Fiber Optic Port Specifications

Table 2 lists the maximum operating distances for the AT-MC13 media
converter.

Table 3 lists the cabling specifications for the twisted pair port.

Table 2. Maximum Operating Distance

Speed

Port

Type of

Connector

Maximum

Operating

Distance

1

1. Maximum operating distance may be less depending on the duplex mode of the

end-node and the type of fiber optic cabling used with the port.

10 Mbps

10Base-T

RJ-45

100 m (328 ft)

10 Mbps

10Base-FL

ST

2 km (1.2 mi)

Table 3. 10Base-T Twisted Pair Cabling Specifications

Operating

Mode

Cable Type

Maximum

Operating

Distance

10Base-T

Unshielded Category 3 or better

100 m (328 ft)