Troubleshooting
Follow the guidelines below to test and troubleshoot the installation in the
event a problem occurs.
If the PWR LED is OFF, do the following:
If the unit is installed on a desktop, check to be sure that the power
adapter is securely connected to a power outlet and that the power
adapter cable is securely connected to the back of the media
converter.
If the unit is installed in an AT-MCR1 or AT-MCR12 chassis, check
that the unit is fully seated in the slot.
Verify that the power outlet has power by connecting another device
to it.
Try using another power adapter.
If the LINK LED for the twisted pair port is OFF, do the following:
Check that the end-node connected to the port is powered ON and is
operating properly.
Check that the twisted pair cable is securely connected to the twisted
pair port on the media converter and on the remote end-node.
Make sure that the twisted pair cable does not exceed 100 meters
(328 feet) and that you are using Category 3 or better cable.
Verify that the end-node is operating at 10 Mbps and full- or
half-duplex mode if connected to an AT-MC13.