beautypg.com

Allied Telesis AlliedView-EMS 4.0.2 VLAN-Manager User Manual

Page 42

background image


AlliedView™-EMS 4.0.2 VLAN MANAGER USER’S GUIDE

Page 42 of 77

The current firmware version allows you to pre-configure switches that may be

added to the stack in the future. Pre-configured switches are identified by a "Non-

Existing" label that appears above the device panel in the Add VLAN and Modify

VLAN dialog boxes. Ports on pre-configured switches can be included in a VLAN

provided they are not members of a port channel. Any attempt to associate a pre-

configured switch port that is a member of a port channel to a VLAN will result in

the error message: "Port is a ghost port that belongs to a Port-Channel."

VLAN Manager may intermittently fail and may return an error "Confirm valid IP

Address, SNMP settings or login, and if the network is functional." when AT-8000S

devices are in stacked mode. To prevent this, go to File -> Properties and increase

the Retry Timeout value.

6 Device Support