Wiring the Fault Alarm Contact

10

AT-IMC1000T/SFP Industrial Gigabit PoE+ Media Converter User Manual

2.4 Wiring the Fault Alarm Contact

The fault alarm contacts are in the middle of the terminal block connector as the picture shows below. Inserting the
wires, it will detect the fault status which the power is failure or port link failure (for managed model) and form an
open circuit.

FIGURE 2-5 Fault Alarm Contacts

1. Insert the wires into the fault alarm contacts (N. 3 and 4)

Note: The wire gauge for the terminal block should be in the range between 12~ 24 AWG.

2.5 LED Indicators

The LEDs located on the front panel display the power status and network status of the Industrial Media Converter.
Each of them has its own specific meaning as defined in Table 2-1.

Table 2-1: Industrial Media Converter LED Definition

LED

Color

Description

PWR1

Green

On

Power input 1 is active

Off

Power input 1 is inactive

PWR2

Green

On

Power input 2 is active

Off

Power input 2 is inactive

Fault

Red

On

Power input 1 or 2 has failed

Off

Power input 1 or 2 are both functional or no power
inputs

L/A

Green

On

Fiber connected to network

Blink

Networking is active

Off

Fiber not connected to network

SPD

Amber

On

Link to 1000 Mbps network

Off

Not connected to network or not working at speed
of 1000M