Campbell Scientific MD485 RS-485 Multidrop Interface User Manual
Page 51

Appendix D. Digital Cellular Modem to MD485 Network
b. Remote
MD485s
1) Active Ports – “CS I/O and RS-485”
2) Communication Mode – “MD9 Emulation” with address 1, 2,
etc. (unique for each remote MD485 and must agree with
respective MD9 in device map)
3) CS I/O Port Configuration – Modem Enable
4) RS-485 Port Configuration – Desired baud rate
4. PAKBUS
NETWORKING
PC-Modem ---Redwing--null modem---MD485 ----------MD485-DL1
---------
--MD485-DL2
LoggerNet SETUP
a. Setup:
TAPIPort
TAPIRemote
PakBus
Port
CR1000
CR1000_2
b. TAPIPort – TAPI line corresponding to PC's modem
c. TAPIRemote – input digital cellular modem's phone number
d. PakBus Port – defaults
e. Dataloggers – corresponding PakBus address, other setting default,
schedule collections as desired
D-7