Campbell Scientific MD485 RS-485 Multidrop Interface User Manual
Page 47

Appendix D. Digital Cellular Modem to MD485 Network
3. MD9
EMULATION
(POINT-TO-MULTIPOINT)
PC--—Cell Tower--Raven—null modem—MD485----MD485-DL1
----
MD485-DL2
LoggerNet Setup
a. Setup
 IPPort 
 
MD9Base
 MD9Remote 
 
CR10X
 MD9Remote_2 
 CR10X_2 
b. IPPort – Internet IP address/domain name and the Port number (the
Raven template file configures the port to be 3001).
c. MD9Base
—defaults
d. MD9Remotes – appropriate addresses
e. Dataloggers – default settings, schedule collections as desired
MD485 Configuration
a. Base
MD485
1) Active Ports – “RS-232 and RS-485” 
2) Communication Mode – “MD9 Emulation” with address 255 
3) RS-232 Port Configuration – Desired baud rate 
4) RS-485 Port Configuration – Desired baud rate 
b. Remote
MD485
1) Active Ports – “CS I/O and RS-485” 
2) Communication Mode – “MD9 Emulation” with address 1, 2, etc 
(unique for each remote MD485 and must agree with respective 
MD9 in device map) 
3) CS I/O Port Configuration – Modem Enable 
4) RS-485 Port Configuration – Desired baud rate 
4. PAKBUS NETWORKING
PC--—Cell Tower--Raven—null modem—MD485----MD485-DL1
----
MD485-DL2
LoggerNet Setup
a. Setup
 IPPort 
 
PakBusPort
 CR1000 
 CR1000_2 
D-3
