1 ships with list, Quickstart, 1 step 1 — mount the sensor – Campbell Scientific 03002, 03101, and 03301 R. M. Young Wind Sentry Sensors User Manual
Page 8: Ships with list, Step 1 — mount the sensor

R.M. Young Wind Sentry
3.1 Ships With List
The 03002 Wind Sentry ships with:
(1) 03002 Wind Sentry including
03102
anemometer
03302
vane
crossarm
band clamp (pn 4919)
(1) 12" x 1.0" unthreaded aluminium pipe (pn 3659)
(1) Allen wrench (pn 5201)
The 03101 anemometer ships with:
(1) 03101 anemometer
(1) 10" x 3/4" threaded galvanized pipe (pn 12243)
(1) Allen wrench (pn 5201)
The 03301 Vane ships with:
(1) 03301 vane
(1) 10” x 3/4” threaded galvanized pipe (pn 12243)
(1) Allen wrench (pn 5201)
4. Quickstart
4.1 Step 1 — Mount the Sensor
This quick start is for the 03002 wind set. Refer to Section 7, Installation, if
installing just the 03101 anemometer or 03301 vane. Section 7, Installation,
also provides siting information.
Tools required:
• 5/64” Allen wrench
• Allen wrench provided with sensor
• 1/2” open end wrench
• compass and declination angle for the site (see Appendix A)
• small screw driver provided with datalogger
• UV resistant cable ties
• small pair of diagonal-cutting pliers
• 6 – 10” torpedo level
Install the 03002 using:
• Standard 1.0-in. IPS schedule 40 pipe (pn 3659)
• CM220 Right-Angle Mounting Kit (FIGURE 4-1 and FIGURE 4-2),
or
• 17953 1 x 1 inch NU-RAIL Crossover Fitting (FIGURE 4-3)
2