R.M. Young Wind Sentry
The 03002's cable can terminate in:
• Pigtails that connect directly to a Campbell Scientific datalogger
(option –PT).
• Connector that attaches to a prewired enclosure (option –PW). Refer
for more information.
• Connector that attaches to a CWS900 Wireless Sensor Interface
(option –CWS). The CWS900 allows the 03002 to be used in a
wireless sensor network. Refer to
for
more information.
6. Specifications
Features:
• Designed for continuous, long term, unattended operation in adverse
conditions
• Small size, simplicity, and rugged construction provide a quality
instrument for a modest price
• Ideal for wind profile studies
• Compatible with the LLAC4 4-channel Low Level AC Conversion
Module, which increases the number of anemometers one datalogger
can measure
• Campbell Scientific version uses shielded bearings, which lowers the
anemometer's starting threshold
Compatible
Dataloggers: CR200(X)-series
CR800
series
CR1000
CR3000
CR5000
CR510
CR10(X)
CR23X
CR7
21X
6.1 Wind Speed (Anemometer)
Range:
0 to 50 m s
–1
(112 mph), gust survival 60 m s
–1
(134
mph)
Sensor:
12 cm diameter cup wheel assembly, 40 mm
diameter hemispherical cups
Accuracy:
±0.5 m s
–1
(1.1 mph)
Turning Factor:
75 cm (2.5 ft)
Distance Constant
(63% recovery):
2.3 m (7.5 ft)