R.M. Young Wind Sentry

;If WS < starting threshold then set WS = 0
3: If (X<=>F) (P89)
1: 2

X Loc [ WS_ms ]

2: 4

<

3: 0.21

F

4: 30

Then

Do


4: Z=F x 10^n (P30)

1: 0

F

2: 0

n,

Exponent

of

10

3: 2

Z Loc [ WS_ms ]


5: End (P95)

;03002 or 03301 RM Young Wind Direction Sensor measurement - WindDir:
6: Excite-Delay (SE) (P4)
1: 1

Reps

2: 5

2500 mV Slow Range

;5000 mV(slow/60hz) range for CR23X, 21X, or CR7

3: 1

SE

Channel

4: 1

Excite

all

reps

w/Exchan

1

5: 2

Delay (0.01 sec units)

6: 2500

mV

Excitation

;5000 mV for CR23X, 21X, or CR7

7: 3

Loc [ WindDir ]

8: 0.1408 Multiplier

;0.0704 for CR23X, 21X, or CR7

9: 0

Offset

7: If (X<=>F) (P89)
1: 3

X Loc [ WindDir ]

2: 3

>=

3: 360

F

4: 30

Then

Do

8: Z=F x 10^n (P30)

1: 0

F

2: 0

n,

Exponent

of

10

3: 3

Z Loc [ WindDir ]

9: End (P95)

10: If (X<=>F) (P89)
1: 3

X Loc [ WindDir ]

2: 4

<

3: 0

F

4: 3

Then

Do

11: Z=F x 10^n (P30)

1: 0

F

2: 0

n,

Exponent

of

10

3: 3

Z Loc [ WindDir ]

12: End (P95)

13: If time is (P92)
1: 0

Minutes (Seconds --) into a

2: 60

Interval (same units as above)

3: 10

Set Output Flag High (Flag 0)