TABLE 7-4. Parameters for Wind Direction

CR10(X)

CR510
CR200(X)

CR7
21X
CR23X


CR800
CR1000


CR5000
CR3000

Measurement
Range

2500 mV,
slow

5000 mV,
slow/60 Hz

2500 mV,
60 Hz,
reverse
excitation

5000 mV,
60 Hz,
reverse
excitation

Excitation
Voltage

2500 mV

5000 mV

2500 mV

5000 mV

Multiplier 0.1408 0.0704 352 352

Offset 0 0 0 0

7.4.3 Wind Vector Processing Instruction

The Wind Vector output instruction is used to process and store mean wind
speed, unit vector mean wind direction, and standard deviation of the wind
direction (optional) from the measured wind speed and direction values.

7.4.4 Example Programs

The following programs measure the 03002 every 5 seconds, and store mean
wind speed, unit vector mean direction, and standard deviation of the direction
every 60 minutes. Wiring for the examples is given in TABLE 7-5.

TABLE 7-5. Wiring for Example Programs

using the 03002-L

Color Description

CR1000 CR10X

Red

Wind Spd. Signal

P1

P1

Black

Wind Spd. Reference

G

Clear

Wind Spd. Shield

G

Green

Wind Dir. Signal

SE 1

SE 1

Blue

Wind Dir. Excitation

VX 1 or
EX 1

E1

White

Wind Dir. Reference

AG

14