7.6 Set Auto Repeat
Mode

Dec
Hex

254 126

FE 7E

Mode
Mode

Sets key press repeat mode to typematic or hold. In typematic mode if a key press is held, the key value is
transmitted immediately, then 5 times a second after a 1 second delay. In hold mode, the key down value is
transmitted once when pressed, and then the key up value is sent when the key is released. Default is typematic.

Mode

1 byte, 1 for hold mode or 0 for typematic


7.7 Auto Repeat
Mode Off

Dec
Hex

254 96

FE 60

Turns auto repeat mode off. Default is on (typematic).


7.8 Assign Keypad
Codes

Dec
Hex

254 213

FE D5

Key Down Key Up
Key Down Key Up

Assigns the key down and key up values sent to the host when a key press is detected. Defaults are shown below
and can be reset by setting all values to 255.

Key Down

16 bytes, key down values

Key Up

16 bytes, key up values

Table 25: Default Key Down Values

Key Down

A(65)

B(66)

C(67)

D(68)

E(69)

F(70)

G(71)

H(72)

I(73)

J(74)

K(75)

L(76)

M(77)

N(78)

O(79)

P(80)

Table 26: Default Key Up Values

Key Up

a(97)

b(98)

c(99)

d(100)

e(101)

f(102)

g(103) h(104)

i(105)

j(106)

k(107)

l(108)

m(109) n(110) o(111) p(112)