$padto pad timeout value, Dp dial command for udp pad – Horner APG XLt OCS HE-GSM04 User Manual
Page 57

MAN4005-04-EN
GPRS / GSM MODEM Configuration
PAGE 57
22. $PADTO PAD Timeout Value
$PADTO
PAD Timeout Value
Command Function
This command allows the user to query/set the PAD timeout value. Data will be
forwarded to the PAD destination even if the PAD block size has not been
reached if
received from the local host.
Command Functional
Group
Enfora Specific
Command Format Query
Response
AT$PADTO
$PADTO: (0-65535)
OK
Write Format
Response
AT$PADTO =
OK
Read Format
Response
AT$PADTO
$PADTO: <PAD timeout>
Execution Format
Response
N/A
N/A
Parameter Values
The number of tenths of seconds to wait for the receipt of more PAD data before
forwarding the currently accumulated PAD buffer to the PAD destination. A value
of zero disables the PAD timeout feature. If the PAD timeout feature is disabled,
no data will be forwarded to the destination until either an enabled forward
character is received, or the selected PAD buffer size is reached. (50 = 5
seconds)
23. DP Dial Command for UDP PAD
DP
Dial Command for UDP PAD
Command Function
This command is used to invoke the UDP PAD via a dial command.
Command Functional Group
Enfora Specific
Command Format Query
Response
N/A
N/A
Write Format
Response
atdp
Connect
Read Format
Response
N/A
N/A
Execution Format
Response
N/A
N/A
Parameter Values
IP Address of the destination host.
UDP Port number. If no UDP port number is required, a value zero (0) should be
specified here.
Notes
This command will override the AT$PADDST settings for the current connected
session.
Example:
atdp123.456.789.1/0
atdp123.456.789.2/3000
Page 57 of 62 ECN # 956